1.
Neuro Oncol ; 22(11): 1677-1685, 2020 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-32227185

RESUMO

BACKGROUND: Hippocampus is considered to be the seat for neurocognitive functions. Avoidance of hippocampus during radiotherapy to brain may serve to preserve various domains of neurocognition. We aimed to derive radiotherapy dose constraints to hippocampi for preserving neurocognition in young patients with brain tumors by measuring various neurocognitive parameters. METHODS: Forty-eight patients with residual/progressive benign or low-grade brain tumors treated with stereotactic conformal radiotherapy (SCRT) to a dose of 54 Gy in 30 fractions underwent prospective neuropsychological assessments at baseline before SCRT and at 6 months and 2, 3, 4, and 5 years. Hippocampi were drawn as per the Radiation Therapy Oncology Group atlas. Longitudinal change in intelligence quotient scores was correlated with hippocampal doses. RESULTS: Mean volume of bilateral hippocampi was 4.35 cc (range: 2.12-8.41 cc). Craniopharyngioma was the commonest histologic subtype. A drop of >10% in mean full-scale intelligence quotient (FSIQ) scores at 3 and 5 years post SCRT was observed in patients in whom left hippocampus received a mean dose of 30.7 Gy (P = 0.04) and 31 Gy (P = 0.04), respectively. Mean performance quotient (PQ) scores dropped > 10% at 5 years when the left hippocampus received a dose of > 32 Gy (P = 0.03). There was no significant correlation of radiotherapy doses with verbal quotient, or with doses received by the right hippocampus. Multivariate analysis revealed young age (<13 y) and left hippocampus dose predicted for clinically relevant decline in certain neurocognitive domains. CONCLUSIONS: A mean dose of ≤30 Gy to the left hippocampus as a dose constraint for preserving intelligence quotient is suggested. KEY POINTS: 1. Children and young adults with benign and low-grade gliomas survive long after therapy.2. Higher dose to the hippocampi may result in long-term neurocognitive impairment.3. Mean dose of <30 Gy to left hippocampus could be used as a pragmatic dose constraint to prevent long-term neurocognitive decline.


Assuntos
Neoplasias Encefálicas , Glioma , Neoplasias Hipofisárias , Adolescente , Neoplasias Encefálicas/radioterapia , Criança , Feminino , Hipocampo , Humanos , Masculino , Estudos Prospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Resultado do Tratamento
2.
J Cancer Res Ther ; 11(2): 358-63, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26148600

RESUMO

AIMS: To evaluate current focal high precision radiotherapy (RT) techniques to spare hippocampi most optimally, in view of mounting clinical evidence to preserve neurocognition. MATERIALS AND METHODS: Computed tomography/magnetic resonance imaging (CT/MRI) datasets of 10 patients with benign/low-grade brain tumors, treated with focal conformal RT were replanned with helical tomotherapy (Tomo), intensity-modulated radiotherapy (IMRT) with high definition multileaf collimator (HD-MLC), and forward planning stereotactic conformal radiotherapy (SCRT). The primary planning objective was to encompass 99% of planning target volume (PTV) by 95% of prescribed dose (54 Gy/30#). Assessments included target coverage (TC), homogeneity index (HI), and maximum (max) and minimum (min) dose. Hippocampal dose was assessed with mean, maximum, minimum, median dosem and various dose levels. RESULTS: Mean V 95 for PTV coverage in Tomo, IMRT, and SCRT were 99.7, 99.4, and 98.3%, respectively. PTV coverage was significantly better in Tomo and IMRT compared to SCRT (P = 0.03). Tomotherapy (HI ≤ 0.06) and IMRT (HI ≤ 0.06) plans were more homogenous than SCRT (HI > 0.7) (P = 0.00). Right hippocampus mean dose with Tomo (20Gy) was 18.5% less than SCRT (30 Gy); but for left hippocampus, difference decreased to 3.3% (Tomo-32.2Gy and SCRT-34Gy). At 30% dose level, 9% more volume of right hippocampus was treated in IMRT and 20% in SCRT when compared to Tomo plan. At 80% dose, 6 and 12% more volumes were treated with IMRT and SCRT, respectively, in comparison to Tomo plan. For left hippocampus all three techniques were comparable. CONCLUSION: Tomotherapy and Linear accelerator (LINAC)-based IMRT achieved significantly better PTV coverage than forward planned SCRT. Tomo as compared to SCRT and IMRT plans showed trend towards significant sparing of the contralateral hippocampus, in eccentrically located tumors.


Assuntos
Hipocampo/patologia , Imageamento por Ressonância Magnética/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Neoplasias Encefálicas/patologia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Adulto Jovem